Cytoskeleton/Tubulin polymerization assay using >99% pure tubulin, OD based - Porcine (BK006P)/24-30 assays/BK006P
产品编号:BK006P
市  场 价:¥17000.00
场      地:美国(厂家直采)
产品分类: 蛋白类>多肽>多肽合成>
联系QQ:1570468124
电话号码:4000-520-616
邮      箱: info@ebiomall.com
美  元  价:$850.00
品      牌: Cytoskeleton
公      司:Cytoskeleton
公司分类:
Cytoskeleton/Tubulin polymerization assay using >99% pure tubulin, OD based - Porcine (BK006P)/24-30 assays/BK006P
商品介绍
Details

Product Uses Include

  1. Screening compounds for effects on tubulin polymerization activity.
  2. Screening proteins for effects on tubulin polymerization activity.
  3. Determining that tubulin alone (not MAPs) is the target for compounds that affect microtubule polymerization.
  4. Teaching aid for undergraduate/graduate class in pharmacology.

IntroductionThis assay is based on an adaptation of the original method of Shelanski et al. and Lee et al. (1,2), which demonstrated that light is scattered by microtubules to an extent that is proportional to the concentration of microtubule polymer. The resulting polymerization curve is representative of the three phases of microtubule polymerization, namely nucleation, growth and steady state equilibrium. See the About Tubulin page for more information. The assay is optimized for a 96-well format for low CVs and efficient sample handling.

This kit contains the porcine neuronal tubulin of the highest available purity (>99% pure, Cat. # T240). The same type of assay is also available with HTS tubulin (Cat. # BK004P) and can serve as an economical, but slightly less sensitive alternative to BK006P. HTS tubulin (Cat. # HTS03) is >97% pure. Cytoskeleton, Inc. also provides a fluorescence based tubulin polymerization assay in miniaturized format (Cat. # BK011P) making it ideal for high throughput screening.

If you are interested in using either of these tubulin polymerization assays in a high throughput setting, please contact our technical service department for advice and bulk quotes.

Kit contentsThis kit contains enough materials for 24 assays (BK006P). The following reagents are included:

  1. Tubulin, >99% pure, lyophilized (Cat. # T240)
  2. GTP solution (Cat. # BST06)
  3. General tubulin buffer (PEM, Cat. # BST01)
  4. Tubulin glycerol buffer (Cat. # BST05)
  5. Paclitaxel positive control (Cat. # TXD01)
  6. DMSO for paclitaxel.
  7. Half area 96-well plate for polymerization reactions
  8. Manual with detailed protocols and extensive troubleshooting guide.

Equipment needed

  1. 96-well plate spectrophotometer with filters to read optical density at 340 nm.
  2. Multi-channel pipette for rapid pipetting of tubulin

Example resultsThe BK006P kit was used to study the effects of Paclitaxel, a polymerization enhancer and Nocodazole, a polymerization inhibitor on tubulin polymerization (Fig. 1)

bk006res

 Figure 1. Tubulin polymerization curves from kit BK006P. The figure shows a standard polymerization curve (Control curve) containing a 100 µl volume of 3 mg/ml tubulin in 80 mM PIPES pH 7.0, 0.5 mM EGTA, 2 mM MgCl2, 1 mM GTP and 10% glycerol. Polymerization was started by incubation at 37°C and followed by absorption readings at 340 nm. Under these conditions, polymerization Vmax is enhanced 4 fold in the presence of 10 µM paclitaxel and reduced 5.5 fold in the presence of 10 µM nocodazole.

References

  1. Shelanski, M. L., Gaskin, F. and Cantor, C. R. (1973). Microtubule assembly in the absence of added nucleotides. Proc. Natl. Acad. Sci. U.S.A. 70, 765-768.
  2. Lee, J. C. and Timasheff, S. N. (1977). In vitro reconstitution of calf brain microtubules: effects of solution variable. Biochemistry, 16, 1754-1762.
About

For product Datasheets and MSDSs please click on the PDF links below.   For additional information, click on the FAQs tab above or contact our Technical Support department at tservice@cytoskeleton.com

 

  •   For our Tubulin Polymerization (Absorbance) Excel Template please download here.
  •   For our IC50 from Vmax Polymerization Excel Template please download here.
Citations

A.-C. Tsai et al. 2014. In vitro and in vivo anti-tumour effects of MPT0B014, a novel derivative aroylquinoline, and in combination with erlotinib in human non-small-cell lung cancer cells. Br. J. Pharmacol. 171, 122–133.

A.-C. Tsai et al. 2014. Orally active microtubule-targeting agent, MPT0B271, for the treatment of human non-small cell lung cancer, alone and in combination with erlotinib. Cell Death and Disease. 5, e1162.

Chen et al., 2012. Protopine, a novel microtubule-stabilizing agent, causes mitotic arrest and apoptotic cell death in human hormone-refractory prostate cancer cell lines. Cancer Lett. v 315, pp 1-11.

Hartley et al., 2012. Polygamain, a New Microtubule Depolymerizing Agent That Occupies a Unique Pharmacophore in the Colchicine Site. Mol. Pharmacol. v 81 pp 431-439.

Chang et al., 2011. Mycotoxin Citrinin Induced Cell Cycle G2/M Arrest and Numerical Chromosomal Aberration Associated with Disruption of Microtubule Formation in Human Cells. Toxicol. Sci. v 119, pp 84–92.

Risinger et al., 2011. ELR510444, A Novel Microtubule Disruptor with Multiple Mechanisms of Action. J. Pharmacol. Exp. Ther. v 336, pp 652–660.

Faridi et al., 2011. Proteomics indicates modulation of tubulin polymerization by L-menthol inhibiting human epithelial colorectal adenocarcinoma cell proliferation. Proteomics. v 11, pp 2115-2119.

Carletti et al., 2011. Effect of protein glutathionylation on neuronal cytoskeleton: a potential link to neurodegeneration. Neuroscience. v 192, pp 285-294.

O"Boyle et al., 2010. Synthesis and Evaluation of Azetidinone Analogues of Combretastatin A-4 as Tubulin Targeting Agents. J. Med. Chem. v 53, pp 8569-8584.Kushkuley et al., 2009. Neurofilament cross-bridging competes with kinesin-dependent association of neurofilaments with microtubules. J Cell Sci. v 122, pp 3579-86.Chen et al., 2005. A-432411, a novel indolinone compound that disrupts spindle pole formation and inhibits human cancer cell growth. Mol. Cancer Ther. v 4, pp 562-568.Huang et al., 2005. CIL-102 interacts with microtubule polymerization and causes mitotic arrest following apoptosis in the human prostate cancer PC-3 cell line. J. Biol. Chem. v 280, pp 2771-2779.Rouzier et al., 2005. Microtubule-associated protein tau: A marker of paclitaxel sensitivity in breast cancer. Proc. Natl. Acad. Sci. U.S.A. v 102, pp 8315-8320.Jiang et al., 2002. Double blockade of cell cycle at G1-S transition and M phase by 3-iodoacetamido benzoyl ethyl ester, a new type of tubulin ligand. Cancer Res. v 62, pp 6080-6088.Mooberry et al., 1999. Laulimalide and isolaulimalide, new paclitaxel-like microtubule-stabilizing agents. Cancer Res. v 59, pp 653-660.

Faqs

Question 1: What is the difference between this kit and BK004P?

Answer 1: Both the BK004P and BK006P are tubulin polymerization kits that are absorbance-based rather than fluorescence-based. The only difference between the two absorbance-based kits is that BK004P uses 97% pure tubulin (remaining 3% are MAPs) while BK006P uses >99% pure tubulin. This is an important difference because the presence of MAPs means that tubulin polymerization can be examined in the absence of enhancers such as glycerol or taxol with as little as 3 or 4 mg/ml tubulin using the BK004P kit. In this case MAPs act as polymerization enhancers. With BK006P, an enhancer such as glycerol or taxol must be used to drive tubulin polymerization with concentrations <5 mg/ml tubulin. Using tubulin at 5 mg/ml or higher allows for the omission of glycerol or taxol. In some cases, glycerol can interfere with the binding of tubulin accessory proteins or compounds. Assay conditions can easily be altered to test for glycerol interference.

Question 2: Which kit is best for screening a compound/reagent/drµg for its effects on tubulin polymerization?

Answer 2: All 3 tubulin polymerization kits (2 absorbance-based kits, BK004P and BK006P; 1 fluorescence-based kit, BK011P) are well-suited for screening of potential tubulin polymerization enhancers and inhibitors. Each kit has its own pros and cons. For initial compound/drµg screening, we recommend the absorbance-based tubulin polymerization assay BK004P. This kit uses 97% pure tubulin (remaining 3% are MAPs) while BK006P and BK011P use >99% pure tubulin. This is an important difference because the presence of MAPs means that tubulin polymerization can be examined in the absence of enhancers or inhibitors with as little as 3 or 4 mg/ml tubulin using the BK004P kit. To study enhancers, we recommend using 3 mg/ml tubulin, whereas 4 mg/ml tubulin is recommended for inhibitors. In the case of BK004P, MAPs act as polymerization enhancers. With BK006P and BK011P, an enhancer such as glycerol or taxol must be used to drive tubulin polymerization with concentrations <5 mg/ml tubulin. Using tubulin at 5 mg/ml or higher allows for the omission of glycerol or taxol, but requires additional tubulin. In some cases, glycerol can interfere with the binding of tubulin accessory proteins or compounds/reagents/drµgs. However, since BK011P is fluorescence-based, there is increased sensitivity that allows the researcher to use 1/3 as much tubulin with greater sensitivity. Thus, the kit provides 96 assays versus the 30 assays of BK004P or BK006P, thus BK011P is the most economical when requiring >30 assays for the project.

If you have any questions concerning this product, please contact our Technical Service department at tservice@cytoskeleton.com

品牌介绍

Cytoskeleton公司成立于1993年,专注于生物化学和细胞过程研究中的纯化蛋白和便捷试剂盒开发与生产。公司提供药物筛选、信号转导、细胞骨架研究相关的系列试剂盒和产品,尤其以细胞骨架相关研究见长,既能满足于样品较少的科学研究,也可以用于小规模筛选研究和高通量大规模筛选研究。此外,公司还提供微管蛋白,肌动蛋白,小G蛋白,GAPs,GEFs等现有产品的药物筛选服务。

自营商城图标
厂家直采
全球直采 正品优价
正品保障图标
正品保障
厂家直发 有线跟踪
解放采购图标
正规清关
CIF100%正规报关,提供发票
及时交付图标
及时交付
限时必达 不达必赔